UV Testing

UV Transmittance Results

 

International
UV Testing Laboratories
324 South Cedarbrook, Dr.
Auburn, AL 36830
334-444-1036
334-844-1340
Fax 334-844-7340
blstaten@charter.net slatebl@auburn.edu

 

Summary Report

 

October 14, 2004

Daniel Gutting
ATSKO, Inc
2664 Russell S.E.
Orangeburg, SC 29115

Dear Sir,

Eight fabric samples received October 12, 2004 were tested for UV Transmittance properties in accordance with Test method AATCC 183. The data are summarized in the following table. 

FabricSample#%T UVA%T UVBMean UPFLabel UPF 
419
C
26.96
17.83
5.12
1
Untreated Cotton
419
W
12.86
2.85
23.92
20
Waterguard
419
T
15.87
9.88
9.67
5
Tectron
419
P
14.09
6.93
13.43
10
303 Protectant Aerospace
419
B
1.79
1.45
72.03
50+
UV Block
419
K
3.79
1.92
50.45
40
UV Killer
419
ES
21.51
8.35
9.58
5
Escourt Canada

Respectfully submitted,

Dr. B. Lewis Slaten

×
×